Difference No.1 Short Column: A column is considered to be short if the ratio of effective length to its least lateral dimension is less than or equal to 12. It’s buckling tendency is very low. Long Column: A column is ...
Discy Latest Articles
Ultra-High Performance Concrete (UHPC)
adminUltra-High Performance Concrete (UHPC) is a cementitious, concrete material that has a minimum specified compressive strength of 17,000 pounds per square inch (120 MPa) with specified durability, tensile ductility and toughness requirements; fibers are generally included in the mixture to ...
Equilibrium Torsion & Compatibility Torsion
adminEquilibrium Torsion Equilibrium Torsion occurs when the torsional moment is required to be in equilibrium and maximum torsional moment (Tu) cannot be reduced by redistribution of moments. In this case the torsion reinforcement must be provided to resist all of ...
Proper Rebar Placement in Construction Site
adminWe need to be careful about Rebar placement in construction site. We need to know which direction bar will be at bottom & which direction bar will be on top at the same layer of reinforcement. Placement of rebar depends ...
What is the difference between thin and thick shell?
adminShell problems generally fall into one of two categories: thin shell problems and thick shell problems. Thick shell problems assume that the effects of transverse shear deformation are important to the solution. Thin shell problems, on the other hand, assume ...
What is the mechanism for such structures?Are they safe?
adminWe generally see a large portion of Slab is overhanged in different structure. We raise question how such large cantilever is safe? We think really these are cantilever, but actually these are not. Their mechanism is different. See the following ...
Advantage of Hollow Section over I Section
adminThe only advantage of hollow section over I section is resistance against torsion. Most of the material is present away from center of mass of the section. To resist torsion we need maximum portion of material away from its center. ...
Types, Reasons & Prevention of Column Failures
adminWe know generally Columns are axially loaded members in structure. It carries compression force due to gravity loads of the structure. Column fails for different reasons. There are mainly three types of failures occur in columns. These are- 1.Compressive Failure ...
All about Burj Khalifa and Reference CAD File of Floor Plans
adminThe Burj Khalifa known as the Burj Dubai prior to its inauguration in 2010, is a skyscraper in Dubai, United Arab Emirates. With a total height of 829.8 m (2,722 ft, just over half a mile) and a roof height (excluding antenna, but including a 244 m spire ...
Difference between Flat slab and Flat plate slab
adminSlab directly supported on columns without beams are called Flat slabs or flat plates. 86-Year-Old Bodybuilder Becomes Oldest to Ever Compete in Japan parabolan steroid bodybuilder cedric mcmillan dead at the age of 44 Followings are the difference between Flat ...